The GRACO SP3F.0040 SaniForce 2.0 HS Series is a 3-inch air-operated double diaphragm (AODD) pump designed for hygienic transfer applications. It features a 316L stainless steel fluid section and is intended for use in food, beverage, personal care, and pharmaceutical industries where high sanitation standards are required. The pump is engineered to handle a wide range of materials and cleaning chemicals, with multiple elastomer options available for compatibility.
Key Features:
- Air Operated Double Diaphragm (AODD) Pump
- SaniForce 2.0 HS Series, 3″
- 316L stainless steel wetted section, multiple elastomer options
- Up to 150 gpm (567 lpm)
- Up to 125 psi (8.6 bar)
- Tri-clamp and sanitary DIN connections; compatible with various materials and cleaning chemicals
- 3A, ATEX, USP Class VI, CE, 3.1 certification
- Single piece manifolds reduce tri-clamps and gaskets for easier cleaning and maintenance
- Handles solids up to 3.8 inches (96.5 mm) in diameter
- Surface finish options: 125, 32, or 20 Ra
- Optional leak sensors for process integrity
- Pump can be rotated 360 degrees for draining and servicing
- Designed for rigorous, continuous use with quick knockdown for easy cleanability and sanitation
- Lube-free, non-sticking air valve with external serviceability for quick, inexpensive repairs
- All fluid contact materials are FDA-compliant and meet CFR Title 21
Applications:
Ideal for hygienic transfer in food, beverage, personal care, cosmetics, and pharmaceutical industries. Suitable for handling viscous, abrasive, or shear-sensitive fluids and for applications requiring frequent cleaning and sanitation.
Installation Notes:
- Using genuine GRACO parts ensures optimal performance, reliability, and compliance with industry standards. Non-genuine parts may compromise sanitation, safety, and equipment longevity.
- Ensure proper alignment of pump and piping to prevent stress and leaks
- Use appropriate gaskets and seals for sanitary connections
- Install optional leak sensors for added process security
- Rotate pump as needed for draining and maintenance
- Follow manufacturer guidelines for cleaning and sanitizing procedures
- Regularly inspect diaphragms, seals, and valves for wear or damage
- Clean and sanitize pump according to industry and application requirements
- Replace worn or damaged parts with genuine GRACO components
- Lubricate only as specified by manufacturer (note: air valve is lube-free)