Description
Description
A two component, solvent free, heavy duty epoxy tank lining.
Where To Use
For application to steel tank internals to provide corrosion resistance to a range of products
including crude oil, white oils and potable water.
Suitable for application over concrete for lining and secondary containment purposes
Technical Information
The detailed Interline 975 Application Guidelines should be consulted prior to use.
Exact specification for total dry film thickness and number of coats will be dependent upon service enduse requirements. Consult International Protective Coatings for specific advice regarding tank liningapplications.Interline 975 is a solvent free high viscosity material and can be applied by standard airless sprayequipment. Refer to Interline 975 Application Guidelines for detailed information. Apply by airless sprayonly. Application by other methods, e.g. brush or roller, may require more than one coat and is suggestedfor small areas only or initial stripe coating. Heavily pitted areas should be stripe coated by brush, toensure good “wetting” of the surface.Do not apply at steel temperatures below 10C (50F). Surface temperature must always be a minimumof 3C (5F) above dew point. The climatic conditions within the tank must be controlled asrecommended in the Interline 975 Application Guidelines.The relative humidity within the confines of the tank should be controlled using dehumidificationequipment. Where such equipment is not available, a single coat application technique should beemployed to avoid intercoat adhesion problems. Where multi-coat systems are to be used, optimumintercoat adhesion is best achieved by keeping the overcoating interval as short as possible.Exposure to unacceptably low temperatures and/or high humidities during or immediately afterapplication may result in incomplete cure and surface contamination that could jeopardise subsequentintercoat adhesion.After the last coat has cured hard, the coating system dry film thickness should be measured using asuitable non-destructive magnetic gauge to verify the average total applied system thickness. The coatingsystem should be free of all pinholes or other holidays and verified using a suitable method asrecommended in the Interline 975 Application Guidelines. The cured film should be essentially free ofruns, sags, drips, inclusions or other defects. All deficiencies and defects should be corrected. Therepaired areas shall be retested and allowed to cure as specified before placing the finished lining intoservice. Consult International Protective Coatings Interline 975 Application Guidelines for detailed repairprocedures.






Reviews
There are no reviews yet.